William, Terry and all,
>In case you are considering PVC for the ducting, I'd do some research. PVC
>is more prone to buildup of static charges, more difficult to ground and,
>consequently, fire hazard increases. I dunno how much, and I know a couple
>guys that use PVC and haven't had any issues, but it may be worth
>researching if that is your bent.
>
>Just my 2 cents.
>William R. Monroe
Good comment William. The use of PVC is OK provided that a proper
earthing network is installed. A spiral wrap of earth wire (without
insulation) along each runner, properly grounded, will prevent the
generation of potentially explosive static voltages.
Ron O.
--