<DIV><SPAN class=171491412-06022006><FONT face=Arial color=#0000ff =
size=2>Hi
Terry,</FONT></SPAN></DIV>
<DIV><SPAN class=171491412-06022006><FONT face=Arial color=#0000ff =
size=2></FONT></SPAN> </DIV>
<DIV><SPAN class=171491412-06022006><FONT face=Arial color=#0000ff =
size=2>OK,
you've measured the contact area, but my other concern was with ease of
installation. I have a problem figuring out how it will be to hold =
those
rods in place when you install the flanges. My other concern was what if =
these
rods get imbedded and then loose and rattle? I still think it would have =
been
easier to glue a piece of wood on the rail so you wouldn't have to hold =
anything
while installing the flanges. Let us know how things turn
out.</FONT></SPAN></DIV>
<DIV><SPAN class=171491412-06022006><FONT face=Arial color=#0000ff =
size=2></FONT></SPAN> </DIV>
<DIV><SPAN class=171491412-06022006><FONT face=Arial color=#0000ff =
size=2>Marcel</FONT></SPAN></DIV>
<BLOCKQUOTE dir=ltr
style="PADDING-LEFT: 5px; MARGIN-LEFT: 5px; BORDER-LEFT: #0000ff 2px =
solid; MARGIN-RIGHT: 0px">
<DIV></DIV>
<DIV class=OutlookMessageHeader lang=fr dir=ltr =
align=left><FONT face=Tahoma
size=2>-----Message d'origine-----<BR><B>De :</B>
pianotech-bounces@ptg.org [mailto:pianotech-bounces@ptg.org] <B>De la =
part
de</B> Farrell<BR><B>Envoyé :</B> 5 février 2006 =
16:45<BR><B>À :</B>
Pianotech List<BR><B>Objet :</B> Re: Brass Rail to Wood Flange
Conversion<BR><BR></FONT></DIV>
<DIV><FONT face=Arial size=2>Okay guys, please help me understand =
here. I'm
understanding both Ron and Marcel to suggest that the butt flange in =
the
picture below does not have sufficient contact with the action rail. =
Marcel
goes further to suggest, that because of a lack of contact, the metal =
rods
will imbed themselves into the flange and rail and the flange screws =
will
continually loosen.</FONT></DIV>
<DIV><FONT face=Arial size=2></FONT> </DIV>
<DIV><FONT face=Arial size=2>This system has quite a bit of =
contact between
the flange and action rail. The two entire rectangular areas =
(about 12mm
x 5mm each) of the flange above the flange screw and below the =
screw are
in intimate contact with the action rail. Plus it also has the limited =
surface
area of the wires. That's not enough?</FONT></DIV>