<!doctype html public "-//W3C//DTD W3 HTML//EN">
<html><head><style type="text/css"><!--
blockquote, dl, ul, ol, li { padding-top: 0 ; padding-bottom: 0 }
 --></style><title>CA delivery apparatus, verdict</title></head><body>
<div>Attached is a photo (grainy due to reduction) of the drafting
pen</div>
<div>made by<font face="Arial" size="-4" color="#000000"><b> Charvoz
Roos</b></font>. The lever is a quick release for cleaning.</div>
<div>The only place I found on the web for them was from 'used
item'</div>
<div>sites, in drafting sets. They might be out of production.</div>
<div><br></div>
<div>The bottle with either the micro-capillary tube or fine needle
attached</div>
<div>delivered too much material too fast. I forgot to squeeze
the</div>
<div>air out first which would have reduced the flow/dripping
but</div>
<div>that only works for a while. Plus, with the large reservoir
(bottle)</div>
<div>a large unwanted flow has great potential.&nbsp; I want more
control</div>
<div>and goof proof. Emphasis on the later.</div>
<div><br></div>
<div>The lubed syringe with a fine needle was very precise but I would
have</div>
<div>appreciated the added flow control that a screw drive would have
offered.</div>
<div>Time to think about the mechanics of a CA gun (similar to a
caulking gun).</div>
<div>Just need to find a thumb screw or such with ultra fine
threads.</div>
<div><br></div>
<div>The pen delivered a measured amount with precision. It clogged
often</div>
<div>so the wholesale treatment of the bridge would be best served
with the</div>
<div>syringe. A 1/8&quot; bead of glue in the pen wicked right in when
touched on</div>
<div>the base of the pin without a trace and stopped the false
beat.</div>
<div>This would be perfect for spot sizing on the job where
producing</div>
<div>a lubed hypo and subsequent clean-up is prohibitive.</div>
<div><br></div>
<div>A combination worked well too. I placed the pen tip on a crack or
base</div>
<div>of the pin and fed the glue with the syringe. If you keep the
reservoir</div>
<div>to a minimum the flow wicks in without overflow.</div>
<div>The tip of the pen acted as a fine-point interface.</div>
<div><br></div>
<div>I didn't have an open container of CA in which to dip the
pen.</div>
<div>This would have allowed for faster application with the
pen.</div>
<div>I loaded the pen quill from either the bottler or syringe.</div>
<div>But it's loading-up caused me to use the syringe across the
sections.</div>
<div>Perhaps if I had cleaned it better there may not have been such
reaction.</div>
<div><br></div>
<div>There was some minor migration but nothing like from the bottle.
With that,</div>
<div>a cloth and brush kept the surface clean. Any gloss from glue
drying on the</div>
<div>surface was brushed to a matte finish and the bridge looks
undisturbed.</div>
<div><br></div>
<div>The beats are gone and the treble is clean and bright.</div>
<div><br></div>
<div>So, drafting pen for the tool case for spot sizing. Lubed syringe
for extended</div>
<div>bridge pin sizing.</div>
<x-sigsep><pre>-- 
</pre></x-sigsep>
<div><br>
Regards,<br>
<br>
Jon Page</div>
</body>
</html>