<DIV><FONT face=Arial size=2>As I replaced the old brackets I
noticed like Bob said, the new brackets were about 3/32's shorter in
height. This was needed......Originally, while removing this action
"both ends" hammer flange screws had scraped the underside of the pinblock.
I almost wondered if it would come out without damage! </FONT></DIV>
<DIV><FONT face=Arial size=2></FONT> </DIV>
<DIV><FONT face=Arial size=2>NOW...after the new brackets, setting the action
spread to 112.5 mm and a bench regulation I attempted to slide the action
back into the piano. A few regulation screws in the center of the action
will not clear the bottom of the stretcher board. </FONT></DIV>
<DIV><FONT face=Arial size=2></FONT> </DIV>
<DIV><FONT face=Arial size=2>The clearance between the two is at best, very
close but the stretcher board upon measurement is about 1/8 inch lower in the
center of the piano. The ends hammer flange screws are clearing now on the
ends but not by much. Guess enough that they are not the problem.</FONT></DIV>
<DIV><FONT face=Arial size=2></FONT> </DIV>
<DIV><FONT face=Arial size=2>I am reluctant to reduce the dimensions of anything
more than what may be absolutely necessary to clear for future servicing and not
alter the actions calculations. I just feel that the action needs a little more
space to clear safely.</FONT></DIV>
<DIV><FONT face=Arial size=2></FONT> </DIV>
<DIV><FONT face=Arial size=2>Your suggestions ... muchly
appreciated!</FONT></DIV>
<DIV><FONT face=Arial size=2>Jerry Arbeau</FONT></DIV></BODY></HTML>