<span>Hey Everyone, <br>Just installed a grand Dampp-Chaser (new style with the modular plug-ins) and had a weird problem. <br><br>The low water (amber) light would come on if you removed the wet pads from the smart heater bar
<br>and<br>The red pad light would come on when you pulled the water probes up out of the tank<br>Exactly opposite from how it&#39;s supposed to work. <br>&nbsp;<br>Called DC central command and they determined I need to replace the humidistat.
<br>They sent it to me, I installed it, and same problem. <br>Then I went home and grabbed two additional grand dc systems, to try out their humidistats. <br>Both of them did it too.&nbsp; <br><br>Finally....started checking other things, and discovered that the problem was the LED panel.&nbsp; 
<br>Somehow it got wired wrong. <br><br>From now on I&#39;m carrying two systems to an install, so I can avoid the repeat visits. <br><br></span><span>Anyone else run across this? <br>
</span><br><span><br></span>Brad Smith, RPT<br><a href="http://www.SmithPiano.com" target="_blank">www.SmithPiano.com</a><br>