<DIV><FONT face=Arial>Look for the worst (slowest) couple hammers and remove 
butt/hammer assembly from rail. Test flange friction. If tight, treat w/ 
alcohol/water and let dry 24+ hours in low humidity environment.</FONT></DIV>
<DIV><FONT face=Arial></FONT>&nbsp;</DIV>
<DIV><FONT face=Arial>Terry Farrell</FONT></DIV>
<BLOCKQUOTE dir=ltr 
style="PADDING-RIGHT: 0px; PADDING-LEFT: 5px; MARGIN-LEFT: 5px; BORDER-LEFT: #000000 2px solid; MARGIN-RIGHT: 0px">
  <DIV style="FONT: 10pt arial">----- Original Message ----- </DIV>
  <DIV 
  style="BACKGROUND: #e4e4e4; FONT: 10pt arial; font-color: black"><B>From:</B> 
  <A title=toddpianoworks@att.net href="mailto:toddpianoworks@att.net">Matthew 
  Todd</A> </DIV>
  <DIV style="FONT: 10pt arial"><B>To:</B> <A title=pianotech@ptg.org 
  href="mailto:pianotech@ptg.org">pianotech@ptg.org</A> </DIV>
  <DIV style="FONT: 10pt arial"><B>Sent:</B> Friday, August 01, 2008 6:36 
  PM</DIV>
  <DIV style="FONT: 10pt arial"><B>Subject:</B> Spinet Evaluation</DIV>
  <DIV><BR></DIV>
  <DIV>I returned from the spinet evaluation. The elbows will&nbsp;need to be 
  replaced.&nbsp; And with the keys that do work, when you release your finger 
  from the key, the hammer only goes about half way back and you have to move it 
  with your hand to return it.&nbsp; I am suspecting the hammer return springs 
  need replacing.&nbsp; It didn't "feel" like tight flanges, and the hammer 
  springs are where they're suppose to be, but I guess they just are wore 
  out.</DIV>
  <DIV>&nbsp;</DIV>
  <DIV>&nbsp;</DIV>
  <DIV>Thoughts?<BR>Matthew</DIV></BLOCKQUOTE></BODY></HTML>