<html xmlns:v="urn:schemas-microsoft-com:vml" xmlns:o="urn:schemas-microsoft-com:office:office" xmlns:w="urn:schemas-microsoft-com:office:word" xmlns:m="http://schemas.microsoft.com/office/2004/12/omml" xmlns="http://www.w3.org/TR/REC-html40">

<head>
<META HTTP-EQUIV="Content-Type" CONTENT="text/html; charset=us-ascii">
<meta name=Generator content="Microsoft Word 12 (filtered medium)">
<style>
<!--
 /* Font Definitions */
 @font-face
        {font-family:"Cambria Math";
        panose-1:2 4 5 3 5 4 6 3 2 4;}
@font-face
        {font-family:Calibri;
        panose-1:2 15 5 2 2 2 4 3 2 4;}
@font-face
        {font-family:Tahoma;
        panose-1:2 11 6 4 3 5 4 4 2 4;}
@font-face
        {font-family:Consolas;
        panose-1:2 11 6 9 2 2 4 3 2 4;}
 /* Style Definitions */
 p.MsoNormal, li.MsoNormal, div.MsoNormal
        {margin:0in;
        margin-bottom:.0001pt;
        font-size:12.0pt;
        font-family:"Times New Roman","serif";}
a:link, span.MsoHyperlink
        {mso-style-priority:99;
        color:blue;
        text-decoration:underline;}
a:visited, span.MsoHyperlinkFollowed
        {mso-style-priority:99;
        color:purple;
        text-decoration:underline;}
span.EmailStyle17
        {mso-style-type:personal-reply;
        font-family:"Times New Roman","serif";
        color:#215868;}
.MsoChpDefault
        {mso-style-type:export-only;}
@page Section1
        {size:8.5in 11.0in;
        margin:1.0in 1.0in 1.0in 1.0in;}
div.Section1
        {page:Section1;}
-->
</style>
<!--[if gte mso 9]><xml>
 <o:shapedefaults v:ext="edit" spidmax="1026" />
</xml><![endif]--><!--[if gte mso 9]><xml>
 <o:shapelayout v:ext="edit">
  <o:idmap v:ext="edit" data="1" />
 </o:shapelayout></xml><![endif]-->
</head>

<body lang=EN-US link=blue vlink=purple>

<div class=Section1>

<p class=MsoNormal><span style='color:#215868'>Repetition lever set too low.&nbsp;
What you did was the way to check the repetition lever height.&nbsp; Old timers call
that &#8220;rolling the flies&#8221;.&nbsp; If you trip the jack and you just <i>barely</i> feel
the top of the jack scrape the knuckle but it does return fully on its own, the
rep height is correct.&nbsp; The tightness of the jack bushings is another matter.&nbsp;
They should be pretty free.<o:p></o:p></span></p>

<p class=MsoNormal><span style='color:#215868'><o:p>&nbsp;</o:p></span></p>

<p class=MsoNormal><span style='color:#215868'>dp<o:p></o:p></span></p>

<p class=MsoNormal><span style='color:#215868'><o:p>&nbsp;</o:p></span></p>

<p class=MsoNormal><span style='font-size:10.5pt;font-family:Consolas;
color:#215868'><o:p>&nbsp;</o:p></span></p>

<p class=MsoNormal><span style='font-size:10.5pt;font-family:Consolas;
color:#215868'>David M. Porritt, RPT<o:p></o:p></span></p>

<p class=MsoNormal><span style='font-size:10.5pt;font-family:Consolas;
color:#215868'><a href="mailto:dporritt@smu.edu"><span style='color:blue'>dporritt@smu.edu</span></a><o:p></o:p></span></p>

<p class=MsoNormal><span style='color:#215868'><o:p>&nbsp;</o:p></span></p>

<div style='border:none;border-top:solid #B5C4DF 1.0pt;padding:3.0pt 0in 0in 0in'>

<p class=MsoNormal><b><span style='font-size:10.0pt;font-family:"Tahoma","sans-serif"'>From:</span></b><span
style='font-size:10.0pt;font-family:"Tahoma","sans-serif"'>
pianotech-bounces@ptg.org [mailto:pianotech-bounces@ptg.org] <b>On Behalf Of </b>Matthew
Todd<br>
<b>Sent:</b> Sunday, August 17, 2008 5:41 PM<br>
<b>To:</b> pianotech@ptg.org<br>
<b>Subject:</b> Grand Jacks<o:p></o:p></span></p>

</div>

<p class=MsoNormal><o:p>&nbsp;</o:p></p>

<div>

<p class=MsoNormal>I have been observing a grand action, and I was curious
about something (is that a surprise??)<o:p></o:p></p>

</div>

<div>

<p class=MsoNormal>&nbsp;<o:p></o:p></p>

</div>

<div>

<p class=MsoNormal>A)&nbsp; I went and tripped each jack toe and I noticed that
some of them when I tripped the jack toe down, and then released it, the toe
immediately went back up.&nbsp; B)&nbsp; On others, I tripped the jack toe, and
when I released it, the toe went up, but not fully, and I would gently push the
toe and would feel the &quot;click&quot; of the toe returning to it's
position.&nbsp; C)&nbsp; And yet, on a few others, when I pushed down the jack
toe, and then released it, the toe would stay down (assuming a tight flange
here).<o:p></o:p></p>

</div>

<div>

<p class=MsoNormal>&nbsp;<o:p></o:p></p>

</div>

<div>

<p class=MsoNormal>What should be the consistency with each note?&nbsp; I'm
assuming, after I trip the jack toe and release it, the jack should return
fully to where it began.&nbsp; What other&nbsp;problems can there be besides
tight flanges to have the jack not return fully?<o:p></o:p></p>

</div>

<div>

<p class=MsoNormal>&nbsp;<o:p></o:p></p>

</div>

<div>

<p class=MsoNormal>Thanks,<o:p></o:p></p>

</div>

<div>

<p class=MsoNormal>Matthew<o:p></o:p></p>

</div>