<font size=2 face="sans-serif">The gunk in there can really mess up your
consistancy of everything before and after let-off. Good point, Laura.
It'll also change the dw/uw stuffs...All clean = all good to start
with.</font>
<br>
<br><font size=2 face="sans-serif">Paul</font>
<br>
<br>
<br>
<br>
<table width=100%>
<tr valign=top>
<td><font size=1 color=#5f5f5f face="sans-serif">From:</font>
<td><font size=1 face="sans-serif">Laura Olsen <laura-olsen@att.net></font>
<tr valign=top>
<td><font size=1 color=#5f5f5f face="sans-serif">To:</font>
<td><font size=1 face="sans-serif">pianotech@ptg.org</font>
<tr valign=top>
<td><font size=1 color=#5f5f5f face="sans-serif">Date:</font>
<td><font size=1 face="sans-serif">09/07/2011 03:07 PM</font>
<tr valign=top>
<td><font size=1 color=#5f5f5f face="sans-serif">Subject:</font>
<td><font size=1 face="sans-serif">Re: [pianotech] Baldwin grand repetition
spings</font></table>
<br>
<hr noshade>
<br>
<br>
<br><tt><font size=2>If the springs have slots, don't forget to clean them
and polish the springs!<br>
<br>
Laura<br>
<br>
On Sep 7, 2011, at 7:39 AM, Mike Spalding wrote:<br>
<br>
> And all the signs point towards heavy hammers: Replacement hammers
carelessly prepped and installed, DW = 65, UW = 35. But you're right,
I would want to see more measurements and analysis before changing
my suspicion to a conclusion <G><br>
> <br>
> On 9/7/2011 7:28 AM, Al Guecia/Allied PianoCraft wrote:<br>
>> Absolutely Mike, if heavy hammers are indeed the problem.<br>
>> <br>
>> Al -<br>
>> High Point, NC<br>
>> <br>
>> <br>
>> <br>
>> On Sep 7, 2011, at 8:01 AM, Mike Spalding wrote:<br>
>> <br>
>>> On 9/6/2011 3:11 PM, Douglas Gregg wrote:<br>
>>>> Back to the issue of the repetition spring. I know that
that does not<br>
>>>> come into play with measuring down weight but it seems
that it could<br>
>>>> add to the heavy feel. Has anyone else thought about this
design that<br>
>>>> Baldwin uses. It seems to add a lot of pressure on the
back of the<br>
>>>> jack to keep the repetition lever loaded.<br>
>>>> <br>
>>>> Thanks<br>
>>>> Doug Gregg<br>
>>>> Classic Piano Doc<br>
>>> Doug,<br>
>>> <br>
>>> I suspect the reason you are sensing a lot of spring force
on the jack is that it has to be set very strong for the rep lever to support
the heavy hammers. If you were to replace the hammers with ones that
gave you a down weight in the 50 gram range, and regulated the rep springs
appropriately, the jack spring would feel right.<br>
>>> <br>
>>> Mike<br>
>>> <br>
>>> <br>
>> <br>
> <br>
<br>
</font></tt>
<br>
<br>