<font size=2 face="sans-serif">The gunk in there can really mess up your
consistancy of everything before and after let-off. &nbsp;Good point, Laura.
&nbsp;It'll also change the dw/uw stuffs...All clean = all good to start
with.</font>
<br>
<br><font size=2 face="sans-serif">Paul</font>
<br>
<br>
<br>
<br>
<table width=100%>
<tr valign=top>
<td><font size=1 color=#5f5f5f face="sans-serif">From:</font>
<td><font size=1 face="sans-serif">Laura Olsen &lt;laura-olsen@att.net&gt;</font>
<tr valign=top>
<td><font size=1 color=#5f5f5f face="sans-serif">To:</font>
<td><font size=1 face="sans-serif">pianotech@ptg.org</font>
<tr valign=top>
<td><font size=1 color=#5f5f5f face="sans-serif">Date:</font>
<td><font size=1 face="sans-serif">09/07/2011 03:07 PM</font>
<tr valign=top>
<td><font size=1 color=#5f5f5f face="sans-serif">Subject:</font>
<td><font size=1 face="sans-serif">Re: [pianotech] Baldwin grand repetition
spings</font></table>
<br>
<hr noshade>
<br>
<br>
<br><tt><font size=2>If the springs have slots, don't forget to clean them
and polish the springs!<br>
<br>
Laura<br>
<br>
On Sep 7, 2011, at 7:39 AM, Mike Spalding wrote:<br>
<br>
&gt; And all the signs point towards heavy hammers: &nbsp;Replacement hammers
carelessly prepped and installed, DW = 65, UW = 35. &nbsp;But you're right,
I would want to see more measurements and analysis &nbsp;before changing
my suspicion to a conclusion &lt;G&gt;<br>
&gt; <br>
&gt; On 9/7/2011 7:28 AM, Al Guecia/Allied PianoCraft wrote:<br>
&gt;&gt; Absolutely Mike, if heavy hammers are indeed the problem.<br>
&gt;&gt; <br>
&gt;&gt; Al -<br>
&gt;&gt; High Point, NC<br>
&gt;&gt; <br>
&gt;&gt; <br>
&gt;&gt; <br>
&gt;&gt; On Sep 7, 2011, at 8:01 AM, Mike Spalding wrote:<br>
&gt;&gt; <br>
&gt;&gt;&gt; On 9/6/2011 3:11 PM, Douglas Gregg wrote:<br>
&gt;&gt;&gt;&gt; Back to the issue of the repetition spring. I know that
that does not<br>
&gt;&gt;&gt;&gt; come into play with measuring down weight but it seems
that it could<br>
&gt;&gt;&gt;&gt; add to the heavy feel. Has anyone else thought about this
design that<br>
&gt;&gt;&gt;&gt; Baldwin uses. It seems to add a lot of pressure on the
back of the<br>
&gt;&gt;&gt;&gt; jack to keep the repetition lever loaded.<br>
&gt;&gt;&gt;&gt; <br>
&gt;&gt;&gt;&gt; Thanks<br>
&gt;&gt;&gt;&gt; Doug Gregg<br>
&gt;&gt;&gt;&gt; Classic Piano Doc<br>
&gt;&gt;&gt; Doug,<br>
&gt;&gt;&gt; <br>
&gt;&gt;&gt; I suspect the reason you are sensing a lot of spring force
on the jack is that it has to be set very strong for the rep lever to support
the heavy hammers. &nbsp;If you were to replace the hammers with ones that
gave you a down weight in the 50 gram range, and regulated the rep springs
appropriately, the jack spring would feel right.<br>
&gt;&gt;&gt; <br>
&gt;&gt;&gt; Mike<br>