<br>John Hartman wrote
<blockquote TYPE=CITE>>What I said is that the crowning process does not
damage the panel as long
<br>>as it is kept within the elastic range. Your putting the ceiling at
11%
<br>>(witch is equivalent ot 60% RH) is exactly what I said earlier.
<br>&nbsp;
<br><a href="https://www.moypiano.com/resources/#archives"></a>&nbsp;</blockquote>

<p><br>Given that we are dealing with 5.5 % instead of 4.5 % this either
all gets adjusted upwared to 12 %,&nbsp; which pushes RH up a bit as well,
Or you are looking at a 0.8 % overall compression, which what...needs to
be modified to take into consideration the effect bending via crowning
has.
<p>I am under the impresseion that the 0.8 % compression rate is really
just what is the compression level at the interface with the rib, and that
as you move towards the top side of the panel this is significantly less...
tho I dont see yet how to figure this damage. This would seem to lower
the overall damage threshold further.... tho I am not sure yet as to how
much.
<p>Still trying to figure where Ron got 580 psi as perpendicular to grain
FSPL for Sitka when it says 710 psi in the table on page 79 of Hoadly's
book. Thats about a 20 percent increase strengthwise.
<p>RicB
<br>&nbsp;
<br>&nbsp;
<p>--
<br>Richard Brekne
<br>RPT, N.P.T.F.
<br>UiB, Bergen, Norway
<br><A HREF="mailto:rbrekne@broadpark.no">mailto:rbrekne@broadpark.no</A>
<br><A HREF="http://home.broadpark.no/~rbrekne/ricmain.html">http://home.broadpark.no/~rbrekne/ricmain.html</A>
<br><A HREF="http://www.hf.uib.no/grieg/personer/cv_RB.html">http://www.hf.uib.no/grieg/personer/cv_RB.html</A>