<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
<HTML><HEAD>
<META http-equiv=Content-Type content="text/html; =
charset=iso-8859-1">
<META content="MSHTML 6.00.2900.2523" name=GENERATOR>
<STYLE></STYLE>
</HEAD>
<BODY bgColor=#d8d0c8>
<DIV><FONT face=Arial size=2>Hello Cy and list.</FONT></DIV>
<DIV><FONT face=Arial size=2></FONT>&nbsp;</DIV>
<DIV><FONT face=Arial size=2>I find this is an interesting topic =
(micrometer
technique).&nbsp; I find it difficult too to make accurate =
measures.&nbsp; I do
zero my micrometer each time I use it.</FONT></DIV>
<DIV><FONT face=Arial size=2></FONT>&nbsp;</DIV>
<DIV><FONT face=Arial size=2>I prefer measuring the string under =
tension, as I
feel that the major problem with measuring a string is that you must =
obviously
measure a straight portion of it, which, without tension, is quite
tricky.</FONT></DIV>
<DIV><FONT face=Arial size=2>I use the cylinder anvil, in order to =
minimize, at
least on one side, the surface of the anvil that will contact the =
string.&nbsp;
Like you, I do three or four measurements on the same string, always =
using the
friction device, and wobbeling the micrometer while turning the device, =
so that
the string can find it's way under the micrometer, and let read it's =
actual
diameter.&nbsp; I believe (but I am not sure) that errors due to minute =
string
diameter variations are far less important than errors due to string not =
being
perfectly straight under the micrometer anvils.&nbsp; For this reason, I =
always
choose the lowest value of the measures I made as the most probable
one.</FONT></DIV>
<DIV><FONT face=Arial size=2>Even with this method, I found that my =
knowing of
what diameter the string should&nbsp;have (following a rational string =
sheme)
had much influence on the actual reading I do of it's diameter, which is =
no
good, I believe.&nbsp; Or maybe just opposite.</FONT></DIV>
<DIV><FONT face=Arial size=2></FONT>&nbsp;</DIV>
<DIV><FONT face=Arial size=2>I hope to generate comments from more =
experienced
fellows.&nbsp; Anyway, do you expect a half gauge number difference with =
the
desired one to be a real catastrophy ?</FONT></DIV>
<DIV><FONT face=Arial size=2></FONT>&nbsp;</DIV>
<DIV><FONT face=Arial size=2>Best regards.</FONT></DIV>
<DIV><FONT face=Arial size=2></FONT>&nbsp;</DIV>
<DIV><FONT face=Arial size=2>Stéphane Collin.</FONT></DIV>
<DIV><FONT face=Arial size=2></FONT>&nbsp;</DIV>
<BLOCKQUOTE dir=ltr
style="PADDING-RIGHT: 0px; PADDING-LEFT: 5px; MARGIN-LEFT: 5px; =
BORDER-LEFT: #000000 2px solid; MARGIN-RIGHT: 0px">
  <DIV style="FONT: 10pt arial">----- Original Message ----- </DIV>
  <DIV
  style="BACKGROUND: #e4e4e4; FONT: 10pt arial; font-color: =
black"><B>From:</B>
  <A title=741662027@theshusters.org =
href="mailto:741662027@theshusters.org">Cy
  Shuster</A> </DIV>
  <DIV style="FONT: 10pt arial"><B>To:</B> <A =
title=pianotech@ptg.org
  href="mailto:pianotech@ptg.org">Pianotech</A> </DIV>
  <DIV style="FONT: 10pt arial"><B>Sent:</B> Tuesday, November 16, =
2004 2:48
  PM</DIV>
  <DIV style="FONT: 10pt arial"><B>Subject:</B> Measuring strings for
  replacement</DIV>
  <DIV><BR></DIV>
  <DIV><FONT size=2>Should I use the biggest size I've measured, =
assuming there
  may be stretching (especially because of the break), or do I need =
micrometer
  lessons?&nbsp; (Hmm, I should measure the strings on both sides, in =
the
  piano...)</FONT></DIV>
  <DIV><FONT size=2></FONT>&nbsp;</DIV>
  <DIV><FONT size=2>Thanks...</FONT></DIV>
  <DIV><FONT size=2></FONT>&nbsp;</DIV>
  <DIV><FONT size=2>--Cy Shuster--</FONT></DIV>
  <DIV><FONT size=2>Bluefield, WV</FONT></DIV>
  <DIV>&nbsp;</DIV></BLOCKQUOTE></BODY></HTML>