<!doctype html public "-//W3C//DTD W3 HTML//EN">
<html><head><style type="text/css"><!--
blockquote, dl, ul, ol, li { padding-top: 0 ; padding-bottom: 0 }
--></style><title>Re: Sound board panel drying
box</title></head><body>
<div>Hi Terry,</div>
<div><br></div>
<blockquote type="cite" cite>How the heck much pressure are you
pumping into that box?????</blockquote>
<div><br></div>
<div>Not much, but it doesn't take a lot when the walls of the box are
made from 12 mm ply only. The loading on each wall is equal to the
surface area times the air pressure. It doesn't take much pressure to
cause a problem, since the panel bay is big enough to accommodate a
9'6" concert grand panel.</div>
<div><br></div>
<blockquote type="cite" cite>Do you have the production needs to dry a
board that fast?</blockquote>
<div><br></div>
<div>Not really, but the fan is only 125W output. See specs
below;</div>
<div align="center"><br></div>
<div align="center"><img
src="cid:a05100300baf28673060b@[61.8.27.52].1.0"></div>
<div><br></div>
<div>I haven't actually checked the pressure head in the delivery duct
to get an idea of the current flow volume, but it certainly seems to
be flowing adequately.</div>
<div><br></div>
<div>It takes about three hours to reduce the moisture content of
spruce down to 6% from 9% with a heat input of around 1000W. Although
I would be inclined to leave the panel under static conditions for a
couple of extra hours, just in case the moisture gauge is reacting
faster than the panel.</div>
<div><br></div>
<div>Best,</div>
<div>Ron O.</div>
<x-sigsep><pre>--
</pre></x-sigsep>
<div>_______________________<br>
<br>
OVERS PIANOS - SYDNEY<br>
Grand Piano Manufacturers<br>
<br>
Web: http://overspianos.com.au<br>
mailto:info@overspianos.com.au<br>
_______________________</div>