You're not looking in the right place to correct your problem. I would adjus=
t hammer blow distance at 1 3/4".&nbsp; I would set key dip at 3/8". Then, b=
efore doing any more adjusting, turn the action around, and make sure all th=
e jacks are set at the right place under the knuckles. Starting with the fir=
st note, lower the top of the balancier, and make sure the back edge of the =
jack is even with the back edge of the knuckle core. It will be easy to adju=
st this, because you can see the tool right through the balancier window. Li=
ft hammer number one, and go to number two, and so forth. You might be surpr=
ised at how many jacks are in the wrong position. <BR>
<BR>
When you have the jacks in the right position, (you might want to double che=
ck jack height also), go back and work on your after touch. Again, leave the=
 hammer line alone. Removing just .017 might be all you need to get the afte=
r touch you're looking for. <BR>
<BR>
Wim </FONT></HTML>