jiimialeggio wrote: > Ron Nossaman wrote: >> >> Don't seal or line anything. > I was going to insulate to keep running costs down. However, insulation > is useless without sealing. So are you saying that insulation as well is > not useful? That's what I'm saying. The buildings that get driest in the heating season are the ones with the poorest insulation and vapor barrier, and the leakiest windows. Seal and insulate the box, and you'll be steaming panels for a long time to little effect. >> As I recall, you already have a working practical MC gage. > Yup; quite swell it is too. Cool! Ron N
This PTG archive page provided courtesy of Moy Piano Service, LLC