Dale writes,

> drying to 30% R.H./6 % emc, 

Ever wonder how Relative Humidity relates to Equilibrium Moisture Content? I 
know Dale knows, but I just wanted to remind those who don't have it yet, 
that the Wood Handbook is available (FREE!) in electronic form at
http://www.fpl.fs.fed.us/documnts/FPLGTR/fplgtr113/fplgtr113.htm

The subtitle is Wood as an Engineering Material, and you can download a 
chapter at a time (you will need Acrobat Reader for these .pdf files).

The wonderful Table 3-4 lists EMC for various combinations of temperature and 
humidity. For instance, if you are drying a soundboard panel and your hotbox 
is running at 90 degrees F, 30% relative humidity will give you 5.9% EMC. You 
can achieve the same moisture content in the wood in a 130 degree hotbox at 
35% RH.

Bob Davis